Following are the clear cover normally provided to Reinforced Cement Concrete structures, Please note that this may vary as per the Structural DesignCLEAR COVER TO MAIN REINFORCEMENT:
FOOTINGS : 50 mm
RAFT FOUNDATION.TOP : 50 mm
RAFT FOUNDATION.BOTTOM/SIDES : 75 mm
STRAP BEAM : 50 mm
GRADE SLAB : 20 mm
COLUMN : 40 mm
SHEAR WALL : 25 mm
BEAMS : 25 mm
SLABS : 15 mm
FLAT SLAB : 20 mm
STAIRCASE : 15 mm
RET. WALL : 20/ 25 mm on earth
WATER RETAINING STRUCTURES : 20/30 mm
PLINTH BEAM:30 mm

PILING:50 to 75 mm